Bug #652

Problems converting SubSec tags to XMP

Added by Andreas Huggel about 8 years ago. Updated almost 8 years ago.

Status:ClosedStart date:25 Oct 2009
Priority:NormalDue date:
Assignee:-% Done:

100%

Category:metadata
Target version:0.19

Description

Exif SubSec tags which do not contain numbers are wrongly converted to XMP.
E.g., a SubSec tag containing 3 bytes 0, 0, '3' leads to an XMP timestamp which ends in a . and can not be converted back to Exif.

Associated revisions

Revision 1914
Added by Andreas Huggel about 8 years ago

#652: Better conversion of Exif SubSec tags.

History

#1 Updated by Andreas Huggel about 8 years ago

  • Status changed from New to Resolved
  • Target version set to 0.19

#2 Updated by Andreas Huggel almost 8 years ago

  • % Done changed from 0 to 100

#3 Updated by Andreas Huggel almost 8 years ago

  • Status changed from Resolved to Closed